ATG HVM Bollards approved by SIRA (UAE)

Crash-tested perimeter security engineered by ATG Access and supported locally in the UAE and approved by SIRA — from design and approvals through installation, commissioning, and annual maintenance. See our SIRA Crash Ratings Explained for UAE context and model selection.

Important: This page is a general overview. Where SIRA applies, a project-specific Method Statement & Risk Assessment (MS/RA) is prepared and submitted for approval before works start. Authority/landlord permits are followed for every site.

Why ATG Bollards

  • Proven crash ratings across IWA 14-1, PAS 68, and ASTM F2656 ranges.
  • Broad portfolio: automatic retractable, shallow-mount, fixed, removable, and surface-mounted systems.
  • Local delivery: site surveys, civil & MEP coordination, commissioning, O&M manuals, and AMC plans.
  • Integrations: access control, PLC/SCADA, EFO (Emergency Fast Operation), safety loops, LED lids, UPS/manual override. Device options and design notes are covered in Access Control Devices.

Product Range (Quick Guide)

SP400 Family (Automatic)

Core automatic HVM range. Options for standard depth, shallow, super-shallow, and surface-mount arrays.

  • Ratings: PAS 68 and IWA 14-1 variants
  • Options: EFO, LED lids, heaters
  • Best for: high duty-cycle entrances


View ATG Datasheet (PDF)

Stealth (Automatic)

High-performance automatic bollard for critical entrances where reliability and serviceability are key.

  • Rating: IWA 14-1 (7,200 kg @ 80 kph)
  • Features: EFO, manual pump, anti-burst valves
  • Best for: CNI, finance, embassies


View ATG Datasheet (PDF)

SP1000 / SP1200 (Automatic)

Ultra-high performance automatic bollards for severe impact conditions.

  • SP1000: PAS 68 + ASTM M50 P1
  • SP1200: PAS 68 (30,000 kg @ 80 kph)
  • EFO and PLC/SCADA integration


View ATG Datasheet (PDF)

SPK12 (Fixed / Removable)

Fixed or removable HVM bollard for permanent perimeters with occasional access requirements.

  • Rating: IWA 14-1 (7,200 kg @ 80 kph)
  • Low penetration, tight stand-off
  • Sleeves & finishes available


View ATG Datasheet (PDF)

Shallow / Super-Shallow Arrays

Arrays designed for congested utilities or restricted depths.

  • Typical depths ≈ 128–178 mm (model dependent)
  • Surface-mount options for events/temporary
  • Rapid install, minimal disruption


View ATG Datasheet (PDF)

Accessories & Controls

Complete system packages with safety and control interfaces.

  • Control panels, UPS, EFO
  • Safety loops, photocells, beacons & sounders
  • Heaters, LED lids, decorative sleeves

Learn more

Selected Projects in the Middle East

  • Dubai International Airport — Aviation program
  • Bluewaters Island, ICD Brookfield Place, The Hills, Tiara United Towers — Commercial
  • Boardwalk, Dubai Creek — Public realm
  • Atlantis, Taj Dubai — Hospitality
  • Dubai Outlet Mall — Retail
  • United Nations HQ (Bahrain) — Government

Case Study — ADGM Square (Abu Dhabi)

Installation of Stealth Automatic Security Bollards: eleven systems with UP/DOWN/STOP-REVERSE/EFO, safety loops, central “Lockdown”, anti-burst valves, manual hand pump, and red LED lids. Commissioning and acceptance followed a formal FDS/SAP process.

Crash Ratings — Quick Guide

ASTM F2656: M30/M40/M50 with P-ratings (penetration). IWA 14-1: vehicle type, mass & speed (e.g., 7,200 kg @ 80 kph). PAS 68: legacy UK format (e.g., 7,500 kg @ 80 kph).

See the full explanation

Foundations & Utilities (Summary)

  • Depths: standard vs. shallow/super-shallow vs. surface-mount (model dependent).
  • Drainage: pit drainage/sumps; local dewatering during installation as required.
  • MEP: power, control ducting to panels; PLC/SCADA and access-control integration.
  • Footprints: clear stand-off, safety devices, and maintenance access zones.

Read more about foundations & installation

Documentation & Compliance in the UAE

  • Shop drawings, MS/RA, test plans, inspection requests
  • O&M manuals, spares lists, warranties
  • SIRA/authority coordination where in scope; traffic management & HSE on site

See our documentation & handover package

What to Expect on Site

  1. Site survey & threat/civils review
  2. Design, drawings & approvals
  3. Civils & MEP preparation
  4. Installation & commissioning
  5. Training, handover & AMC

Full process details

FAQs

What delivery lead times should we expect?
Typical ranges vary by model and finish. For UAE projects, allow time for approvals, civils, and utilities coordination. Request a live schedule during the site assessment.
Can we install shallow-mount where services are dense?
Yes — shallow/super-shallow arrays are designed for reduced depths. A services scan and civil review will confirm final feasibility and spacing.
What happens on power failure?
Systems fail-secure or to a defined safe state per design. Manual hand pumps and UPS/EFO options are available; agree fail-state logic at design stage.
Which finishes are available?
Stainless steel (e.g., 316), powder-coated RALs, or decorative sleeves. LED lids and beacons/sounders can be added for visibility and safety.
Do you provide maintenance?
Yes — annual maintenance contracts (AMC) with scheduled inspections, lubrication, calibration, and parts replacement as required.