eCatalogue 2026 — Security Bollards (Low-speed impact / storefront protection)
This catalogue covers security bollards for low-speed impact resistance (storefront / pedestrian interface protection).
Models include fixed (deep or shallow), removable (deep or shallow), and manual retractable.
Download / View this catalogue
Core material: Steel (EN 10219 S355J). Finish: Hot dip galvanizing (optional stainless steel sleeve/cover).
How the catalogue states performance
- Impact resistance: 25 kJ and 100 kJ options are shown across the models.
- Equivalent test references (as listed):
- 25 kJ ≈ PAS 170 (2,500 kg @ 16 kph) and ASTM F3016 (5,000 lb @ 10 mph)
- 100 kJ ≈ PAS 170 (2,500 kg @ 32 kph) and ASTM F3016 (5,000 lb @ 20 mph)
- System note: Install a minimum of 3 bollards as a system to achieve the stated crash rating (catalogue note).
- Foundation note: Must be installed within an approved, reinforced concrete foundation (catalogue note).
Quick selection (choose by installation depth and access need)
- SDL — Deep Fixed: fixed bollards with deeper embedment and specified C40 foundation sizes.
- SSL — Shallow Fixed: fixed bollards with shallow embedment (200 mm below ground shown).
- RDL — Deep Removable: removable bollards with deeper embedment and socket/foundation allowance (catalogue provides foundation size).
- RSL — Shallow Removable: removable option with 200 mm below ground shown.
- MDL — Manual Retractable: manual retractable bollards with 1500 mm below ground shown and a C40 foundation size.
Common specification pattern (what repeats across the range)
- Core diameters: 141.3 mm (5.5″) and 168.3 mm (6.5″) are used across the models shown.
- Optional sleeve/cover diameters: 168.3 mm (6.5″) and 219.1 mm (8.5″) (optional).
- Typical height above ground: 1000 mm is shown across the model tables.
- Wall thickness: 9.5 mm and 11 mm options are shown.
- Finish: hot dip galvanizing; optional stainless sleeve.
Models and key numbers (from the catalogue tables)
SDL — Security Deep Fixed (SDL1 / SDL2)
- Above / below ground: 1000 mm above; 500 mm (SDL1) or 650 mm (SDL2) below.
- Foundation (C40): 600×600×600 mm (SDL1) or 600×600×750 mm (SDL2).
- Impact resistance: 25 kJ (SDL1) or 100 kJ (SDL2).
- Weight (core): 44 kg (SDL1) or 64 kg (SDL2).
SSL — Security Shallow Fixed (SSL1 / SSL2)
- Above / below ground: 1000 mm above; 200 mm below (both).
- Impact resistance: 25 kJ (SSL1) or 100 kJ (SSL2).
- Note: must be installed within approved, reinforced concrete foundation; min 3 bollards for rating.
RDL — Security Deep Removable (RDL1 / RDL2)
- Above / below ground: 1000 mm above; 500 mm (RDL1) or 600 mm (RDL2) below.
- Foundation (C40): 650×600×650 mm (not included).
- Impact resistance: 25 kJ (RDL1) or 100 kJ (RDL2).
RSL — Security Shallow Removable (RSL1 / RSL2)
- Above / below ground: 1000 mm above; 200 mm below (both).
- Impact resistance: 25 kJ or 100 kJ (as listed).
- Note: must be installed within approved, reinforced concrete foundation; min 3 bollards for rating.
MDL — Security Manual Retractable (MDL1 / MDL2)
- Above / below ground: 1000 mm above; 1500 mm below.
- Foundation size (C40): 600×600×1600 mm.
- Weight (core): 85 kg (MDL1) or 100 kg (MDL2).
- Impact resistance: 25 kJ or 100 kJ (as listed).
Spacing quick-check (for planning)
The catalogue includes a quick spacing method for vehicle access planning:
- L (mm) = passage width for vehicle access
- N = number of bollards required
- Ø (mm) = bollard diameter
- d (mm) = distance between bollards
N = (L − d) / (Ø + d)
d = (L − (Ø × N)) / (N + 1)
Installation notes (important)
System requirement: Install minimum 3 bollards to achieve the stated crash rating (catalogue note).
Foundation requirement: Must be installed within an approved, reinforced concrete foundation (catalogue note).
Drainage: If soil is impermeable or groundwater is high, provide a positive drain to a nearby drain/sump (by others).
Corrosion restoration (after fabrication / welding marks): heat tint/free-iron removal and passivation to ASTM A967 (ref. ASTM A380).
Need a quotation or model shortlisting?
Send us: (1) model family (SDL / SSL / RDL / RSL / MDL), (2) required impact resistance (25 kJ or 100 kJ),
(3) preferred finish (galvanized core only or optional SS sleeve), and (4) slab/foundation constraints (shallow vs deep).