Testability pays for itself on day one. Specify pressure/voltage test points, diagnostic signals, and modular components so commissioning (631–636) and SAT (638) run cleanly. Provide space for probes, simulate inputs/loads, and enable counters/health pings (541–542). Add acceptance hooks in enclosures (347) and a service-tool checklist to support long-term reliability (842, 734). Include one-sentence context that naturally links upward to the parent hubs (this section and the chapter hub). Add SIRA context with a link to SIRA Bollards (UAE) when relevant. Link installation pages only if helpful: What to Expect and Installation Guide.
356.1 Built-in test points
Provide safe electrical and hydraulic measurement taps (519, 512). Test points speed SAT for an HVM bollard lane.
Design test points into both power and control stages so technicians can measure voltage, current and pressure without dismantling hardware. Use shrouded jacks and labelled manifolds tied to the Power Test Points list, and expose a clear legend inside the door card. For hydraulics, provide glycerin-filled gauges or safe bleed ports near the HPU.
Keep measurement points upstream and downstream of critical devices (contactors, relief valves) so faults are isolated quickly. Reference each point in the commissioning script (631–636) and map it to the lane’s SAT / Witness Procedure (638).
| Aspect | What matters | Where to verify |
|---|---|---|
| Performance | Tested system (bollard + footing) | Crash Ratings Explained |
| Operations | Duty cycles, fail-state, safety | Installation Guide |
356.2 Diagnostic signals
Expose statuses, faults, and counters (541–542). Signals let teams diagnose a crash rated bollard quickly.
Standardize status bits for “Request → Authorize → Execute,” safety chain healthy, alarm philosophy states, and latched faults. Provide cycle counters, ops/hour, and last-fault code locally on the HMI and upstream to BMS/SCADA (346, 533). Ensure the health ping flags stale comms.
356.3 Commissioning aids
Add simulator sockets, bypass keys, and jogs (529, 633). Aids reduce time-to-proof for HVM bollard logic.
Fit guarded simulator sockets for loops and photo-eyes so teams can prove the interlock matrix (352) without exposing people to moving parts. Provide a maintenance jog function with deadman action and low speed, and a key-switch to bypass non-critical indicators during setup (never bypass safety devices & measures).
356.4 Modular swapping
Use plug-in drives, valve blocks, and HMIs. Modularity keeps a crash rated bollard lane available (842, 365).
Adopt service levels & availability targets and design around swap-friendly modules: pre-terminated looms, slide-out HPUs, and quick-disconnect valve blocks. Label connectors to the panel wiring standard (527) and keep handset/HMI replacements tool-less where possible to cut MTTR.
356.5 Access for measurement
Leave probe space near high-risk nodes (528). Access improves HVM bollard MTTR.
Lay out the enclosure (347, 528) with finger-safe access around terminals, shunts, and pressure taps. Use swing frames and keep 25–40 mm probe space around dense terminal blocks. Mark zero-energy verification points and provide illumination for dark roadside cabinets.
356.6 Simulated inputs & loads
Allow loop/beam simulation and dummy loads (344–345). Simulation proves crash rated bollard behavior safely.
Include a loop simulator mode and panel-mounted resistive dummy loads for lamps and beacons. This lets you verify timers and the state machine (342) without vehicle traffic. Document expected responses in 633–636 and cross-reference each with the interlock matrix (352).
356.7 Logging & counters
Standardize cycles/ops/hour and error counts (542). Logs benchmark HVM bollard performance.
Record counters locally and upstream, with rollover rules and timestamps. Keep an SOE (change-of-state) log with enough depth to support operational dashboards (544). Use stable tags so KPIs remain consistent across firmware versions (537).
356.8 Acceptance test hooks
Map each feature to SAT steps (634–638). Hooks streamline approvals at a crash rated bollard site.
Add labelled witness points (e.g., “Loop A simulate,” “EFO inhibit prove”) and capture-ready ports for screenshots and pressure readings. Align with FDS / SAP / ITP / SAT (710) and include these hooks in your integration documentation (539) so authorities can verify quickly. In UAE contexts, note SIRA evidence expectations and link to the SIRA Bollards (UAE) hub.
356.9 Service tool checklist
List laptop cables, gauges, and firmware loaders (522, 529). Tools keep HVM bollard support predictable.
Maintain a lane-specific kit: PLC/relay programming leads (522), loop and beam simulators (529, 344–345), hydraulic pressure gauge set, multimeter with fused probes, spare fuses/relays, and the most common common spares. Store the checklist inside the door card and reflect it in the preventive maintenance plan (734).
Related