Storefront use; similarities/differences vs PAS 170.

ASTM F3016 focuses on storefront risk: accidental roll-throughs, short run-up distance events, and glazing protection at low speeds. This page explains scope, test setup, vehicles/speeds, and reporting so you can present credible submittals. It also shows how to avoid misuse—when site realities demand an HVM solution or crash-rated bollard, escalate to the appropriate higher-energy standard and evidence set. Include one-sentence context that naturally links upward to the parent hubs (this section and the chapter hub). For UAE approvals, see SIRA Bollards (UAE). If installation details are in scope, also see What to Expect and Installation Guide.

Important: This is a general guide. For live projects we develop a tailored Method Statement & Risk Assessment (MS/RA) and align with authority approvals (e.g., SIRA) where in scope.

442.1 Purpose & scope

Defines a standardized way to assess low-speed impact performance for storefront and public-realm measures. Useful where hostile risk is low and an HVM bollard isn’t justified. Clarifies what PAS 170-1 covers vs what only a crash rated bollard standard addresses (411–416, 434).

ASTM F3016 addresses incidental impacts (driver error, mis-gear, slow roll-through) rather than deliberate, high-energy attacks. You’ll use it to evidence protection for glazing, doors, and pedestrian edges with vehicle penetration distance and damage observations suited to low energies. When credible hostile scenarios exist, step up to IWA 14-1 or ASTM F2656 pages in this chapter.

AspectWhat mattersWhere to verify
PerformanceTested system (post + footing) & as-tested configurationLow-Speed Evidence & Documentation
OrientationImpact face, line, and clear-gapReading Ratings
InstallationFoundation dimensions, concrete, cure, fixingsInstallation Guide

442.2 Test articles & setup

Specifies how the barrier/post is mounted, foundation notes, and measurement zones. Emphasize that installation must mirror the testbed to claim performance. If your context later escalates to hostile risk, move to HVM bollard selection (432).

In practice, treat the “article” as a system: post, sleeve (if any), anchors or socket, and concrete mass. Small changes in embedment depth, spacing to walls, or paving build-up can change outcomes. Document bases, reinforcement, and rating-critical dependencies so reviewers can compare like-for-like against your submittals.

442.3 Vehicles, speeds, masses

Outlines low-speed vehicle classes and impact bands used in ASTM F3016. Record actual storefront context (222–224) so the selected device isn’t misapplied where a crash rated bollard is required.

Capture your vehicle classes, realistic speed estimates, and run-up. F3016 test bands represent short approach distances with cars/light goods vehicles; heavier vehicles or longer approaches point to higher-energy standards. Note any orientation dependency if your frontage has angled approaches.

442.4 Measurements & acceptance

Explains penetration/overrun style measurements and pass/fail logic at low energy. Keep evidence tables and photos aligned to your site layout and clear gaps (232, 322).

Define your penetration line (defend line) and tolerance. Record penetration distance, overrun at low speed, debris fields, and damage to glazing/frames. Acceptance is scenario-led: preventing entry to the protected zone with acceptable structural damage. Use consistent camera framing and a wide→detail photo set so reviewers can audit your claim.

442.5 Reporting & marking

What a valid test report includes, how products are identified, and labeling conventions. Tie report fields to your submittals (431, 444, 938) to avoid reviewer pushback.

Expect product identifiers, article description, foundation details, impact speed/mass, report number, and traceable media. Reference the same IDs in your evidence & documentation index and cover letters so the submission pack reads cleanly from overview to detail.

442.6 Typical applications

Shopfront glazing, café spill-outs, pedestrianized edges—places with benign vehicles and short run-up (214, 231). Not a substitute for an HVM bollard where credible hostile scenarios exist (212, 432).

Use F3016 for retail, mall concourses, forecourts, and fuel-station shops with tight approach geometry. Combine with good egress width, signage, and kerb lines. Where emergency or service access is needed, pair low-speed devices with controlled gates and clear blue-light routes.

442.7 Limits & pitfalls

Low-speed energy only; foundation/config sensitivity; mis-reads of penetration photos. When in doubt, escalate to crash rated bollard mapping and equivalence checks (414, 421).

Common issues: using sleeve-only “upgrades” without verifying the foundation class; assuming “pass” at one speed implies higher-speed performance; ignoring site comparability. If threat conditions change or credible worst case grows, set an upgrade trigger to migrate to HVM standards.

442.8 Mapping to HVM standards

How to explain differences vs IWA/ASTM/BS crash standards without implying equivalence. Use purpose/tier matrix (235) and anti-downgrade clauses (435) to prevent substitutions.

F3016 ≠ IWA 14-1/ASTM F2656. Avoid weak “energy parity” claims; vehicles, anchors, and arrays are different. Use the Purpose/Tier Matrix and the standards equivalency checklist to communicate limits, then lock outcomes with anti-downgrade wording.

442.9 Using ASTM F3016 in specs

Write performance clauses that lock the tested configuration, installation, and evidence. Add upgrade triggers so a future threat change cleanly moves you to an HVM or crash rated bollard (433, 446).

Structure your spec: (a) reference F3016 for the low-speed case; (b) name acceptable families/variants and rating-critical dependencies; (c) require submittals to include reports, unedited test footage, and photos; (d) include an upgrade trigger to IWA/F2656 where risk increases.

Related

External resources

442 ASTM F3016 Storefront / Low-Speed Tests — FAQ

Does a pass to ASTM F3016 mean the bollard is crash-rated?
No. F3016 is a low-speed storefront test. Crash-rated performance requires standards such as IWA 14-1 or ASTM F2656, which use higher energies, different vehicles, and stricter acceptance criteria.
When should I escalate from F3016 to an HVM standard?
Escalate when credible hostile scenarios exist (212), when approach/run-up is long (222–224), or when vehicles heavier than the F3016 bands are plausible. Use the Purpose/Tier Matrix (235) to document the decision.
Can I change sleeves, heights, or foundations and still claim F3016 performance?
Only if the changes fall within documented tolerances and preserve the as-tested configuration. Lock rating-critical dependencies and require evidence in the submission pack (444) to avoid silent downgrades.
What should be in my submission pack for a storefront project?
Include the F3016 report and media, product IDs, foundation details, layout with clear-gaps, and a reader guide. Cross-reference items in your transmittal and index per our Evidence & Documentation page (444).